Adjust pump speed lvad pdf

This is the physiological aspect of physiological control. Left ventricular assist device design design valveless only one moving part rotor rotor spins on bloodlubricated bearings rubies designed for minimization of blood damage all motor drive and control electronics are outside of the implanted blood pump speed range. These devices are available in most heart transplant centers. Support devices inpatient, outpatient, and transitions of. The lvad is a batteryoperated, mechanical pumptype device thats surgically implanted. It is a rotary mechanical pump powered with batteries and connected to a controller that sets the pump speed. A ventricular assist device vad is an electromechanical device for assisting cardiac circulation, which is used either to partially or to completely replace the function of a failing heart.

Adaptive pump speed algorithms to improve exercise. In previous studies, it has been shown that lvad pump flow increases with exercise 15,18. Left ventricular support adjustment to aortic valve. This patient had a fixed hw lvad speed of 2500 revolutions per minute rpm. A presentation from the new orleans conference 2015 focusing on the counterbalancing forces impacting how we should set the lvad rpm. Lvad patients had more hospitalizations for vad related complications but had a better quality of life.

Fifteen of 20 patients bearing lvad jarvik 2000 enrolled in the study successfully. In the second ecg, interference frequency was 15 per 400 ms, reflecting lvad speed of 2600 rpm. The control variable in is ut t, where t is the electric pump motor power, which can be regulated to adjust the pump speed of the lvad to meet the physiologic demands e. The left ventricular assist device lvad is a rotary mechanical pump that is implanted in patients with congestive heart failure to help the left ventricle in pumping blood in the circulatory system. Impact of hemodynamic ramp testguided hvad speed and. Pvl appearance in the setting of lvad transforms from a trapezoidal shape to a. Normally, middle cerebral artery mean flow velocity increases from.

Heartmate ii lvad as permanent option for heart failure. Clinical implications of physiologic flow adjustment in cont. These constant speed setting or manual adjustment are adequate for short period useage of lvads, but are insuf. Pump speed is conventionally adjusted by a clinician, which is referred to as an operatorintheloop approach fig. Setting the lvad pump speed at rest generally involves a compromise between. In the higher lvef group, the impact of lvad pump speed reduction was minimal. Page 176 under the following conditions, the pump can only be started from the system monitors clinical or settings screen by pressing the pump start button. The response to speed change was different between the two groups. Lvad pump speed increase is associated with improvement of.

Stepwise increases in lvad speed will coincide with similar. Lvad speed adjustment according to a functioning aortic valve has hypothetic advantages but could lead to submaximal support. Nevertheless, in most cases manual speed adaptations could be performed. Ventricular assist devices bja education oxford academic. Left ventricular assist device lvad for heart failure. Medical management of patients with a left ventricular. Adaptive pump speed algorithms to improve exercise capacity in patients supported with a leftventricular assist device may 2017 studies in health technology and informatics 236. Smart tip lvad inlet cannula the penn state research. Left ventricular assist devices lvad will undoubtedly have an increasing role due to the aging population, anticipated concomitant increase in the prevalence of endstage heart failure, and improvements in lvad technology and outcomes.

No contact within pump when running durable driveline thin 4. Lvad pump speed increase is associated with increased peak exercise cardiac output and vo2, postponed anaerobic threshold and improved ventilatory efficiency. A new control system for left ventricular assist devices. In current practice, pump speeds are selected to optimize lv unloading while. The rotary type pumps are controlled by varying the pump motor current to adjust the amount of blood flowing through the lvad. Implantable medical devices american heart association. As of february 4, 2014, thoratec has received four 4 reports 0. Control engineering techniques are used to automatically adjust pump speed to maintain a userspecified set point which can be constant or time varying. If a low flow state occurs, an alarm will be heard, and the controller display will show a yellow triangle and low flow call message. The controller of the gpi continuously adjusts the reference value pi to take into account changes in pulmonary venous return.

Notably, suction can be prevented during the adjustment of the pump speed, since there are no sign switches of slope and the pulsatility of the pump flow remains unchanged. Each ecg with this phenomenon had the same frequency across all ecg leads. Troubleshooting the left ventricular assist device. Continuousflow left ventricular assist devices cflvads improve functional capacity in. In the clinical setting, flow is affected by the pump speed, as well as the preload atrial or ventricular pressure, afterload arterial pressure, inflow cannula resistance, outflow cannula resistance, and tubing length. Left ventricular assist devices for lifelong support. Replace, stitch or over sew av during initial vad surgery if moderate to severe ai preop pump speed should be set to maintain intermittent av. May 20, 2014 lvad speed adjustment according to a functioning aortic valve has hypothetic advantages but could lead to submaximal support. Federal law usa restricts this device to sale by or on the order of a physician. Its not about the pump kathleen brown ccrn, anpbc wmchealth, good samaritan hospital advanced heart failure 1. In the clinical setting, the pump speed is commonly set at an arbitrary speed immediately on insertion and pump speed increased marginally once hemodynamic stability is achieved. Technical care of the lvad the lvad requires regular care and system checks, including powersource changes, daily selftests, and driveline dressing changes. Suction detection and feedback control for the rotary left.

Continuousflow left ventricular assist devices lvad have emerged as the standard of care for advanced heart failure. Modeling, estimation and control of cardiovascular systems. Severe right heart failure after lvad surgery is a serious complication up to 35% of patients receiving a continuous flow lvad developed post operative rv failure postoperative rv failure is associated with high rates of mortality 1943%, and worse survival after cardiac transplant postlvad rv failure is also associated with. These lvads are sensitive to preload and afterload, because the intrinsic dependency of the pump flow from the pump s head pressure aortic pressureleft ventricular pressure 21.

This pump can provide an alternative way for the blood to flow with a higher rate between the ventricle and the aorta for hf patients. The autonomous tuning of the pump speed is not discussed in this work, since our objective is to evaluate the. The system controllers backup battery is not installed. Excessive speed bolus fluids add inotropic support adjust pump speed suction event hypovolemia excessive unloading of ventricle by device arrhythmias bolus fluids lower pump speed treat arrhythmias j heart lung transplant. Successful lvad therapy depends on continued active management following implantation. Do not use this device in pregnant women or any woman likely to become pregnant during her period of lvas support. Heartmate ii lvad insertion the lvad used in this investigation was the heartmate ii lvad, which is a continuous. Patients wear a controller and are allowed, under certain circumstances, to adjust the pump speed according to their activity level. A left ventricular assist device lvad is a pump that we use for patients who have reached endstage heart failure. Circulatory support devices inpatient, outpatient, and. Can the patient be defibrillated while connected to the device.

Left ventricular assist device lvad stanford health care. Thoratec heartmate ii instructions for use manual pdf download. If this happens, reconnect the driveline to the controller as soon as possible to restart the pump. If the patient can be defibrillated, is there anything i have.

Relationship between pump speed and exercise capacity during. Smart tip lvad inlet cannula the penn state research foundation. A growing fetus may dislodge the pump, which may result in device failure or fatal hemorrhage. Increase pump speed under echo guidance hypertension arterial pressure monitoring consider vasodilators, diuretics decrease in pump flow and power dehydration physical examination, echocardiography fluid administration, adjust diuretics suction events in device pump speed higher than volume in lv reduce pump speed hypotension. Another important etiology for a lowflow reading on the lvad controller is pump thrombosis. A moderate increase in lvad pump speed during exercise did not improve exercise tolerance.

Hemolysis, pump thrombus, and neurologic events in continuous. The lvad is a batteryoperated, mechanical pump type device thats surgically implanted. Pumprelated cannulation site, heat generation patientrelated afib, infection managementrelated inr, low speed symptoms heart failure hemolysis ldh plasma free hgb 40. Adaptive pump speed algorithms to improve exercise capacity. Oct 04, 2015 left ventricular assist devices lvad will undoubtedly have an increasing role due to the aging population, anticipated concomitant increase in the prevalence of endstage heart failure, and improvements in lvad technology and outcomes. Vad speed rpm flow lmin pulsatility index pi power in watts perform a system check selftest on the controller by pressing and holding down the battery button until the test begins.

Traditionally echocardiography has been used to adjust lvad speed to achieve proper unloading. In hf patients a co increase with a higher lvad pump speed is. Clinical implications of physiological flow adjustment in. Dealing with surgical left ventricular assist device. Page 1 the heartmate ii lvas pocket system controller has been prescribed for 2,142 patients, either at the time of the implantation of the heartmate ii lvad, or as a replacement for an older controller model epc system controller. The consequences of an open aortic valve policy on exercise capacity and hemodynamics have not yet been investigated systematically. Often the rpms the speed are increased as the controller attempts to adjust to the thrombosis with an increase in. Pump power is the amount of energy required to spin the lvad rotors at the specific speed. Discuss lvad placement and other treatment modalities. These lvads are sensitive to preload and afterload, because the intrinsic dependency of the pump flow from the pumps head pressure aortic pressureleft ventricular pressure 21. We surgically implant the lvad, a batteryoperated, mechanical pump, which then helps the left ventricle main pumping chamber of the heart pump blood to the rest of the body. However, the increase in pump speed filled circles in the figure was associated with higher cardiac output and improved cerebral perfusion during light exercise i. Effect of alteration in pump speed on pump output and left v. Suction detection and feedback control for the rotary.

Indication is new york heart association class 4 heart failure, ejection fraction adjust the pump speed in the prehospital setting. In addition to using edv to adjust pump speed, we have developed a control system to adjust speed based on either lv enddiastolic pressure edp or peaktopeak pressure pppk to assess cardiac preload. We tested the hypothesis that, in heart failure hf patients with left ventricular assistance device lvad, an acute increase of co obtained through changes in lvad pump speed is associated with peak exercise and anaerobic threshold vo2 increase. Pump flow is generated by the speed of the rotating impeller and depicts the amount of total circulating blood volume out of the left ventricle. The third ecg had a frequency of 17 per 400ms, reflecting lvad speed of 2500 rpm. The maximum lvad speed change in the hr group was 300 rpm, whereas the maximum lvad speed change was 160 rpm in the control group. Medical management of patients with a left ventricular assist. The lvad patients had a higher rate of adverse events of which gastrointestinal gi bleeding was the major. It helps maintain the pumping ability of a heart that cant effectively work on its own. Only parameter to adjust speed impeller spins more rapidly greater volume of blood displaced heartmate 2. With a continuous flow left ventricular assist device. It is not possible to adjust the pump speed in the prehospital setting. Do i need to heparinize the patient if it slows down. Pump speed is automatically reduced to the low speed limit setting to avoid suction then slowly.

One important challenge in using such a device is the desire to. If the patient is wearing a battery holster, the numbers must be read from the controller. Lvad pump flow does not adequately increase with exercise. Early perioperative rv failure is a major complication associated with lvad insertion. Jun 20, 2019 more lvad patients met the primary endpoint vs. Lvad pump speed increase is associated with increased peak. Conversion of lvad to bivad stseacts latin america cardiovascular surgery conference 2018 24 167 lvad alone,71 planned bivad and 28 delayed bivad pvads similar patient characteristics in the bivad group when patients at risk for isolated lvad support failure are identified, proceeding directly to bivad. The left ventricular assist device lvad is such a device. The function of vads is different from that of artificial cardiac pacemakers.

As compared to current fixed speed pump control system, the proposed control system will provide pump flow that adapts to physiologic demand. The columbia ramp study required full anticoagulation, reducing the lvad speed to 8,000 rpm, echocardiographic measures at baseline, and sequential measures every 2 min as the pump speed was. Left ventricular support adjustment to aortic valve opening. Modelling and control of a failing heart managed by a left. They randomly performed two incremental exercise protocols one exercise protocol was performed with the usual fixed lvad pump speed set at rest range. The next section briefly describes control theory techniques used in lvad control. Effects of pump speed changes on exercise capacity in patients. Using a combination of central venous pressure cvp and pulmonary capillary wedge pressure pcwp, one can create a construct that details 5 patient pro. Valsalva and positional changes, and pacing adjust ments. Display provides pump information speed rpm power watts vad blood flow lmin when an alarm occurs, the pump information is replaced by the alarm information heartware controller display screen caution. Replace, stitch or over sew av during initial vad surgery if moderate to severe ai preop pump speed should be set to maintain intermittent av opening under echo guidance. Easy to implant, implement support, adjust flow, and manage system disposable polycarbonate blood pump with standard 38 connectors. As with any surgical procedure, lvad implantation is associated with an adverse event profile. Potential complications implantation of a ventricular assist device vad is an invasive procedure requiring general anesthesia, a median sternotomy, a ventilator and cardiopulmonary bypass.

Think of this value as a synonym to cardiac output which is measured in lmin. Caring for patients with a left ventricular assist device. Although the lvad can successfully treat hf symptoms, this is predicated on the fact that pump speed is optimized and that concomitant medical therapy is properly used. Pump speed is the only modifiable setting after lvad implantation. Clinical management of continuousflow left ventricular. Hemolysis, pump thrombus, and neurologic events in. Chronic ldh elevation after left ventricular assist device. Clinicians rely on feedback from observations of patient and pump parameters and make adjustments to pump speed in order to match these parameters to clinically relevant set points. Adjust pump speed suction event hypovolemia excessive unloading of. Effect of alteration in pump speed on pump output and left. The pulsatility gradient which is calculated from the gradient of the pi gpi with respect to pump rotational speed 50 has been proposed to be used as the physiologic control variable to adjust the lvad pump speed. Troubleshooting the left ventricular assist device mdedge. Clinical implications of physiologic flow adjustment in.

1463 635 1496 627 1107 878 1293 1151 834 1452 140 1049 1419 1575 347 1478 1316 1613 1354 1169 24 1369 394 440 723 527 82 377 335 1023 475 1433 1040 418